From Certificate to Data: What NCSLI Canada 2026 Signals for ISO/IEC 17025 Labs

pH meter and sample bottles on a lab bench, connected to an edge device

By Trucision staff

Key takeaways: Three sessions at the 2026 NCSL International Canadian Conference point the same way: calibration and test results are becoming data that systems exchange and act on. Labs should prepare to ingest digital calibration certificates, document and record decision rules for every conformity statement, and replace result-producing spreadsheets without losing traceability.

The technical program at the 2026 NCSL International Canadian Conference (Montréal, November 17–19) points in one direction. Calibration and test results are becoming data that systems exchange and act on, not documents that people file. Three sessions frame the change well, and each carries a lesson for lab managers outside metrology too.

1. Digital Calibration Certificates: the PDF is no longer the deliverable

In Digital Calibration Certificates (DCC): A Foundation for Digital Transformation in Metrology, Christophe Boubay of Beamex will address a gap most labs live with daily. Instruments, calibration labs, asset management systems and enterprise applications all need the same measurement data. Yet certificates are still built for a human to read.

A DCC is a structured, machine-readable certificate. The receiving system can read the values, uncertainties and traceability chain directly, with no retyping.

What to do now:

  • Count how many certificates your team re-keys each month, and where errors appear.
  • Ask your calibration providers whether they issue, or plan to issue, digital certificates.
  • Check whether your LIMS or asset system can ingest structured certificate data, or only stores attachments.

2. Decision rules: consistency is the audit question

Jim Salsbury of Mitutoyo will present Decision Rules and Statements of Conformity. ISO/IEC 17025:2017 requires a lab to agree on and apply a decision rule when it states conformity to a specification. The standard does not say which rule to use.

The result is variation. One technician applies guard bands; another reports a bare pass/fail. An auditor or customer then asks how a borderline result was called, and the record cannot answer.

What to do now:

  • Document the decision rule for each test or calibration type, and confirm it with customers.
  • Store the rule, the measured value and the uncertainty with each result, so every conformity call can be reconstructed.
  • Treat a mismatch between the stated rule and the applied rule as a nonconformity, and track it.

3. Off the spreadsheet, without losing traceability

Sajiv Perera of Measurement Canada will present An extensible platform for in-house lab software – progress on thermometry. The abstract describes moving Measurement Canada's approval and calibration labs from spreadsheets to cloud-enabled software within tight IT constraints. On Day 3, Mitchell Jones of IndySoft will make the case for purpose-built calibration and asset management software.

Spreadsheets fail labs in predictable ways: unvalidated formulas, copied files, and no audit trail of who changed what. Replacing them is not just a tooling choice. The new system has to keep traceability, uncertainty budgets and record integrity intact.

What to do now:

  • List every spreadsheet that produces a reported result. Those are your highest-risk files.
  • For each one, confirm the formulas are validated and the file is locked and versioned.
  • Migrate the ones tied to your accredited scope first.

The common thread: lab data that holds up

Digital certificates, consistent decision rules and validated software all serve one goal. Every result should be traceable, reproducible and defensible, whether the reader is an auditor, a customer or another system. Connected instruments, the subject of Ryan Kershaw's (WIKA) IIoT session, will only raise the volume of data that must meet that bar.

FAQ

What is a digital calibration certificate (DCC)?

A structured, machine-readable calibration certificate. Software can read its values, uncertainties and traceability information directly instead of a person re-keying them from a PDF.

Does ISO/IEC 17025 specify which decision rule to use?

No. ISO/IEC 17025:2017 requires a lab to agree on and apply a decision rule when it states conformity, but it does not prescribe a specific rule.

Why are spreadsheets a risk in accredited labs?

Formulas can change without validation, copies drift apart, and most spreadsheets keep no audit trail of who changed what. That makes reported results hard to defend in an audit.

Related reading

Free download: decision rule and spreadsheet audit template

A ready-to-use template to record the decision rule for each test type and rank your result-producing spreadsheets by risk, so you know what to fix before your next assessment. Send me the template.

Want calibration state and results linked at record level, without re-keying? Book a 30-minute call with the Trucision team.

Trucision is not affiliated with NCSL International. Session details are summarized from the official conference program.

Get started

Find the right plan to modernizeyour product line

We work with OEM product and service leaders to identify the highest-value starting pointy- whether that’s a specific instrument line, a service tier launch, or a compliance gap. Most engagement scope in one session.
Name *
Company
Email *
Role
What are you working on ? *

Thanks!
Your form has been submitted.

Please complete all mandatory fields before submitting.